Page 10 of 16 Techno Strobe™ 168 User Manual (Rev. 2)
4. OPERATION
(DMX)
Set the product in DMX mode to control with a DMX controller.
1. Connect the product to a suitable power outlet.
2. Connect a DMX cable from the DMX output of the DMX controller to the DMX input
socket on the product.
Starting Address
When selecting a starting DMX address, always consider the number of DMX channels
the selected DMX mode uses. If you choose a
starting address that is too high, you could
restrict the access to some of the product’s channels.
The Techno Strobe™ 168 uses up to 2 DMX channels in its 2-channel personality DMX
mode, which defines the highest configurable address to 511. The DMX
is configured through the DIP switches located on the back panel.
If unfamiliar with DMX or DIP switches, download the DMX Primer from
www.chauvetlighting.com.
Settings
DIP Switch 1 2 3 4 5 6 7 8 9
Value 1 2 4 8 16 32 64 128 256
Select the desired starting address by setting DIP switches [1]~[9] to On or Off
sum of the value of the DIP switches in the On
position matches the desired address
number.
Refer to the examples below for more information.
Examples
1. To select DMX address 1, set DIP switch [1] to On.
2. To select DMX address 64, set DIP switch [7] to On.
3. To select DMX address 31, set DIP switches [1], [2], [3], [4], and [5] to On.
(1 + 2 + 4 + 8 + 16 = 31)